Heating wire for cold room doors and refrigerated showcases IC heating cord

Heating wire for cold room doors and refrigerated showcases IC heating cord

Download
our documentation
(PDF - 183 Kb)

Applications

  • Framing of cold room doors and negative cabinets
  • Doorstep of cold room
  • Demisting of refrigerated showcases

Avantages

  • No over-thickness at junctions heating part/cold leads
  • Heating part and cold leads are mechanically and electrically shielded

technical data

  • Maximum maintening temperature (power ON) : +140 °C
  • Maximum exposure temperature (power OFF) : +180 °C
  • Standard power : 30W/m
  • Standard voltage : 230 V
  • Standard lengths (multiple of 0.5 m) : from 1 to 8 m
  • Tinned-copper braid from one end to the other end, including cold lengths

Use precaution

  • The heating cable or cold lead must not be shortened
  • The heating cable must not touch any sharp edged parts
  • The heating cable must not cross or touch itself at any place